Haben Sie Fragen? Einfach anrufen, wir helfen gerne: Tel. 089/210233-0
oder besuchen Sie unser Ladengeschäft in der Pacellistraße 5 (Maxburg) 80333 München
+++ Versandkostenfreie Lieferung innerhalb Deutschlands
Haben Sie Fragen? Tel. 089/210233-0

Model-based control of permanent magnet synchronous motors with inter-turn winding short circuit

45,80 €*

Sofort verfügbar, Lieferzeit: 1-3 Tage

Produktnummer: 1825baf31c94d34bc88559670bcc35f3a9
Produktinformationen "Model-based control of permanent magnet synchronous motors with inter-turn winding short circuit"
System reliability and fault tolerance are essential features in safety-critical applications with permanent magnet synchronous motors (PMSMs). An inter-turn winding short circuit is one of the most common and serious fault cases in PMSMs. Hence, the fault-tolerant control of PMSMs with an inter-turn winding short circuit is a crucial task. This work aims for an optimal fault-tolerant operation of PMSMs in case of an inter-turn winding short circuit. For this task, a magnetic equivalent circuit (MEC) based modeling framework is derived. MECs allow for the systematic consideration of magnetic saturation and non-fundamental wave behavior of electric motors. The high model accuracy of the resulting real-time capable model is demonstrated by a comparison with measurements both in the fault-free case and in case of an inter-turn winding short circuit for a three-phase and a dual three-phase PMSM, respectively. The MEC model of the PMSMs builds the foundation for the design of a model-based fault-identification scheme and a model-based fault-tolerant torque control strategy. The characteristic parameters of the winding fault are estimated by the fault-identification method and subsequently used in the fault-tolerant control algorithm. The developed nonlinear control strategy has a cascaded structure comprising a one-step model-predictive control (MPC) and subordinate PI current controllers. The feasibility of the model-based fault-identification scheme and the high torque control performance of the proposed fault-tolerant control strategy is proven by a number of different experiments performed on a test stand with the three-phase PMSM. Moreover, the advantages of the dual three-phase PMSM regarding fault tolerance are demonstrated in numerical simulations.

Sie möchten lieber vor Ort einkaufen?

Sie haben Fragen zu diesem oder anderen Produkten oder möchten einfach gerne analog im Laden stöbern? Wir sind gerne für Sie da und beraten Sie auch telefonisch.

Juristische Fachbuchhandlung
Georg Blendl

Parcellistraße 5 (Maxburg)
8033 München

Montag - Freitag: 8:15 -18 Uhr
Samstags geschlossen